Bracket the unknown
Turn a base guess and interval into clearly labeled zones on one coated screen.
Screen room calibration, without the guesswork
Build a bracketed step test, turn a 21-step wedge reading into a corrected time, or recalculate after moving a lamp. This browser tool plans the test and does the correction math; it does not replace a calibrated exposure film.
Build a test plan ↓Classic masked strip test
Bracket one educated guess across 3–10 zones.After the base exposure, begin with only zone 1 uncovered. Reveal one more numbered zone for each added interval; the final zone stays at the base time.
5 zones · 4 card moves
Setup details
New exposure test ·
Emulsion: Mesh:
Light: Coating:
After washout — fill by hand
Best zone: Final exposure:
Notes:
Latest setup saved only in this browser. No account, upload, or remote calculation.
Exposure depends on the whole screen-making system. Exposure Bench starts from a time you already have, then helps you test around it or adjust one controlled variable. It never claims that mesh count alone can predict the answer.
Turn a base guess and interval into clearly labeled zones on one coated screen.
Use the target from your emulsion process and the observed solid step to calculate a repeatable correction.
Apply the inverse-square starting adjustment when a point-like lamp moves, then confirm with a new test.
Method boundary: manufacturers say exposure varies with equipment, emulsion, mesh, coating, contact, and shop conditions. See the primary guidance from Chromaline,Ulano, and theStouffer step-wedge factor table.
Three short field guides explain what the calculator can prove, how to run the exposure, and where a retest is safer than another formula.
Expose several useful times on one screen with your own artwork and an opaque card.
Read guide →5 minTranslate a solid-step result into a correction without treating one target as universal.
Read guide →5 minSeparate lamp, distance, mesh, emulsion, coating, film, contact, and process drift.
Read guide →No. Start from the emulsion maker's guidance or your last working time, then run a physical test on your own screen-making setup.
Only for the 21-step correction mode. The classic masked test works with your normal positive and an opaque card.
No. Exposure Bench plans a manual masked test and calculates corrections from your observations. It does not replace a calibrated neutral-density film or imitate a proprietary test positive.
The latest setup stays in this browser's local storage. Print the result if you need a durable bench record, test history, or a copy for another device.